Abstract
In this paper, we want to show how we can gain more from a Kaibel distillation column by considering a degree of freedom which is normally not used. Two methods are used to study the effect of vapour split manipulation, namely a shortcut method and rigorous simulations. Using a case-study, we show that we may not be able to operate close to minimum energy requirement for some feed disturbances as we have the vapour split fixed.