To main content

Corrosion Evaluation of MEA Solutions by SEM-EDS, ICP-MS and XRD

Abstract

The target of this work is to evaluate three analytical techniques, ICP-MS, SEM-EDS and XRD, which can be applied in corrosion monitoring of ethanolamine based post-combustion CO2 capture plants. The work is based on analyses of the solvent and 316 SS cylinders used in thermal degradation experiments. ICP-MS is used for the determination of total Fe, Cr and Ni of the solutions as an indication of corrosivity. Additionally, the cylinder surface was examined with SEM-EDS and XRD was used for the identification of corrosion products. Finally, a discussion is given on the various techniques, their limitations and advantages.
Read publication

Category

Academic article

Client

  • Research Council of Norway (RCN) / 189998

Language

English

Author(s)

  • Georgios Fytianos
  • Seniz Ucar
  • Andreas Grimstvedt
  • Hallvard Fjøsne Svendsen
  • Hanna K. Knuutila

Affiliation

  • Norwegian University of Science and Technology
  • SINTEF Industry / Process Technology

Year

2016

Published in

Energy Procedia

ISSN

1876-6102

Publisher

Elsevier

Volume

86

Page(s)

197 - 204

View this publication at Cristin