To main content

Power losses in the three-phase three-limb transformer due to common and differential mode of dc-bias

Abstract

Geomagnetically induced currents (GICs) and the converter modulation effect are the two main causes for dc magnetisation in power transformers. It is well known that a small dc-bias can saturate a large transformer and thereby generate high unbalanced magnetising currents, imposing a serious risk of excessive power losses and local overheating. Magnetising currents due to GIC phenomena have been studied extensively, whereas studies on converter related dc-bias are few. In particular, a discussion on loss characteristics related to converter modulation lacks. In this study, the dc-bias of common mode and differential mode in a three-phase, three-limb transformer is investigated experimentally. Additionally, to interpret the physical phenomena, the system was modelled using the finite element method. The results revealed that the power losses are significantly influenced by the dc current direction, arrangement of the structural parts, and the method of winding connection.
Read publication

Category

Academic article

Client

  • Research Council of Norway (RCN) / 255178

Language

English

Author(s)

Affiliation

  • Norwegian University of Science and Technology
  • SINTEF Energy Research / Elkraftteknologi

Year

2021

Published in

IET Electric Power Applications

ISSN

1751-8660

Publisher

Institution of Engineering and Technology (IET)

Volume

15

Issue

11

Page(s)

1488 - 1498

View this publication at Cristin